{"id":6935,"date":"2021-02-10T15:05:34","date_gmt":"2021-02-10T13:05:34","guid":{"rendered":"https:\/\/blog.federnshop.com\/tipos-de-resortes-de-extension-de-tension\/"},"modified":"2021-02-10T15:05:38","modified_gmt":"2021-02-10T13:05:38","slug":"tipos-de-resortes-de-extension-de-tension","status":"publish","type":"post","link":"https:\/\/blog.federnshop.com\/es\/tipos-de-resortes-de-extension-de-tension\/","title":{"rendered":"Tipos de resortes de extensi\u00f3n de tensi\u00f3n"},"content":{"rendered":"<p><a href=\"https:\/\/blog.federnshop.com\/wp-content\/uploads\/Formelzeichen_Zugfedern_komplett.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6876\" src=\"https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder.jpg\" alt=\"Muelle de extensi\u00f3n de tensi\u00f3n de carrera\" width=\"600\" height=\"345\" data-wp-pid=\"1930\" srcset=\"https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder.jpg 800w, https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder-300x173.jpg 300w, https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder-600x345.jpg 600w, https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder-400x230.jpg 400w, https:\/\/blog.federnshop.com\/wp-content\/uploads\/Hubspannung_Zugfeder-200x115.jpg 200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p style=\"text-align: right;\"><a href=\"https:\/\/blog.federnshop.com\/wp-content\/uploads\/Formelzeichen_Zugfedern_komplett.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Descripci\u00f3n F\u00f3rmula s\u00edmbolo resortes de tensi\u00f3n<\/a><\/p>\n<p>Antes de interpretar el<a href=\"https:\/\/blog.federnshop.com\/es\/muelles-de-traccion-de-informacion\/\"> resorte de extensi\u00f3n<\/a> Debe aclararse si el tipo de estr\u00e9s pretendido es un<strong> est\u00e1tico<\/strong> o un<strong> estr\u00e9s din\u00e1mico<\/strong> hechos.<\/p>\n<p>No se pueden dar valores generales de resistencia a la fatiga para cargas din\u00e1micas en resortes de tracci\u00f3n, ya que<a href=\"https:\/\/blog.federnshop.com\/es\/muelles-de-traccion-de-informacion\/\"> Puntos de flexi\u00f3n de los ojales<\/a> Pueden ocurrir tensiones adicionales, algunas de las cuales exceden las tensiones permisibles. Por lo tanto, los resortes de tensi\u00f3n solo deben someterse a cargas est\u00e1ticas si es posible. Si no se puede evitar el estr\u00e9s din\u00e1mico, se debe optar por<a href=\"https:\/\/blog.federnshop.com\/es\/muelles-de-extension-con-forma-de-ojal\/\"> Ojales<\/a> renunciar y<a href=\"https:\/\/blog.federnshop.com\/es\/muelles-de-extension-con-forma-de-ojal\/\"> enrollado o atornillado en las piezas de los extremos<\/a> desplegar. Cuando los resortes de tensi\u00f3n est\u00e1n sujetos a cargas din\u00e1micas, es importante realizar una prueba de vida en condiciones de funcionamiento posteriores. Un refuerzo de la superficie por shot peening no se puede realizar o solo con un gran esfuerzo debido a los giros poco espaciados.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/blog.federnshop.com\/es\/tipos-de-resortes-de-extension-de-tension\/#Tension_estatica_en_el_resorte_de_extension\" >Tensi\u00f3n est\u00e1tica en el resorte de extensi\u00f3n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/blog.federnshop.com\/es\/tipos-de-resortes-de-extension-de-tension\/#Tension_dinamica_en_el_resorte_de_extension\" >Tensi\u00f3n din\u00e1mica en el resorte de extensi\u00f3n<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Tension_estatica_en_el_resorte_de_extension\"><\/span>Tensi\u00f3n est\u00e1tica en el resorte de extensi\u00f3n<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Carga constante en el tiempo (est\u00e1tica) o carga variable en el tiempo con menos de 10,000 carreras en esfuerzos de carrera peque\u00f1os o totales (\u03c4h = \u03c42 &#8211; \u03c41) hasta 0.1 x resistencia a la fatiga (\u03c4kh = \u03c4k2 &#8211; \u03c4k1).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Tension_dinamica_en_el_resorte_de_extension\"><\/span>Tensi\u00f3n din\u00e1mica en el resorte de extensi\u00f3n<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>La tensi\u00f3n din\u00e1mica en los resortes se define como tensiones que cambian con el tiempo con m\u00e1s de 10,000 cambios de carga o tensiones de carrera (\u03c4h) sobre 0,1 x resistencia a la fatiga (\u03c4kh) con tensi\u00f3n de carrera constante y variable.<\/p>\n<p>El esfuerzo cortante existente se determina como sigue.<\/p>\n<p>Esfuerzo cortante por fuerza: <img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=%5Ctau%3D%5Cfrac%7B8DF%7D%7B%5Cpi%20d%5E%7B3%7D%7D\" alt=\"\\ tau = \\ frac wpml_curved wpml_value = '8DF' \/ wpml_curved {\\ pi d ^ wpml_curved wpml_value = '3' \/ wpml_curved }\" align=\"absmiddle\"><\/p>\n<p>Esfuerzo cortante de la trayectoria: <img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=%5Ctau%3D%5Cfrac%7BGds%7D%7B%5Cpi%20nD%5E%7B2%7D%7D\" alt=\"\\ tau = \\ frac wpml_curved wpml_value = 'Gds' \/ wpml_curved {\\ pi nD ^ wpml_curved wpml_value = '2' \/ wpml_curved }\" align=\"absmiddle\"><\/p>\n<p>Para la carga din\u00e1mica, la tensi\u00f3n de carrera corregida debe calcularse debido al aumento de tensi\u00f3n.<\/p>\n<p>Esfuerzo cortante corregido: <img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=%5Ctau_%7B%7Bk%7D%7D%3Dk%5Ctau\" alt=\"\\ roc\u00edo_ {} = k \\ tau\" align=\"absmiddle\"><\/p>\n<p>Voltaje de carrera corregido: \u03c4kh = \u03c4k2 &#8211; \u03c4k1<\/p>\n<p>Donde se aplica k (seg\u00fan Bergstr\u00e4sser):<\/p>\n<p><img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=k%3D%5Cfrac%7B%5Cfrac%7BD%7D%7Bd%7D%2B0%2C5%7D%7B%5Cfrac%7BD%7D%7Bd%7D-0%2C75%7D\" alt=\"k = \\ frac {\\ frac wpml_curved wpml_value = 'D' \/ wpml_curved wpml_curved wpml_value = 'd' \/ wpml_curved +0,5} {\\ frac wpml_curved wpml_value = 'D' \/ wpml_curved wpml_curved wpml_value = 'd' \/ wpml_curved -0,75}\" align=\"absmiddle\"><\/p>\n<p>Con el factor de correcci\u00f3n de tensi\u00f3n k, que depende de la relaci\u00f3n de bobinado (relaci\u00f3n entre el di\u00e1metro medio y el grosor del alambre) del resorte, se puede determinar aproximadamente la tensi\u00f3n m\u00e1s alta.<\/p>\n<p>Voltaje admisible: <img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=%5Ctau_%7B%7Bzul%7D%7D%3D0%2C45%20%5Ccdot%20R_%7B%7Bm%7D%7D\" alt=\"\\ dew_ {} = 0.45 \\ cdot R_ {}\" align=\"absmiddle\"><\/p>\n<p><a href=\"https:\/\/blog.federnshop.com\/zugfestigkeit-federwerkstoffe\/\" target=\"_blank\" rel=\"noopener noreferrer\">Valores m\u00ednimos de resistencia a la tracci\u00f3n de materiales de resorte <img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=R_%7B%7Bm%7D%7D\" alt=\"R_ {}\" align=\"absmiddle\"> <\/a><\/p>\n<p>La tensi\u00f3n m\u00e1xima existente \u03c4n en la mayor deflexi\u00f3n del resorte sn se equipara con la tensi\u00f3n permisible. Sin embargo<a href=\"https:\/\/blog.federnshop.com\/es\/relajacion-para-los-muelles\/\" target=\"_blank\" rel=\"noopener noreferrer\"> relajaci\u00f3n<\/a> Para evitar esto, solo el 80% de este recorrido del resorte debe usarse en la pr\u00e1ctica.<\/p>\n<p><img decoding=\"async\" class=\"mathtex-equation-editor\" src=\"https:\/\/chart.apis.google.com\/chart?cht=tx&amp;chl=s_%7B%7B2%7D%7D%3D0%2C8%5Ccdot%20s_%7B%7Bn%7D%7D\" alt=\"s_ {} = 0.8 \\ cdot s_ {}\" align=\"absmiddle\"><\/p>\n<p>&nbsp;<\/p>\n<p><iframe loading=\"lazy\" src=\"https:\/\/www.youtube.com\/embed\/cqsZmGz7Tng\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>Enlaces interesantes:<\/p>\n<ul>\n<li><a href=\"https:\/\/blog.federnshop.com\/es\/tipos-de-resortes-de-compresion-de-tension\/\">Tipos de resortes de compresi\u00f3n de tensi\u00f3n<\/a><\/li>\n<\/ul>\n<ul>\n<li><a href=\"https:\/\/www.federnshop.com\/de\/federberechnung-auswahl.html\" target=\"_blank\" rel=\"noopener noreferrer\">C\u00e1lculo de resorte Gutekunst WinFSB<\/a><\/li>\n<\/ul>\n<ul>\n<li><a href=\"https:\/\/www.federnshop.com\/de\/service_informationen\/federnauslegung.html\" target=\"_blank\" rel=\"noopener noreferrer\">Dise\u00f1o de primavera<\/a><\/li>\n<\/ul>\n<ul>\n<li><a href=\"https:\/\/www.federnshop.com\/de\/service-und-informationen\/technische-beratung.html\" target=\"_blank\" rel=\"noopener noreferrer\">Asesoramiento t\u00e9cnico de Gutekunst Federn<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Descripci\u00f3n F\u00f3rmula s\u00edmbolo resortes de tensi\u00f3n Antes de interpretar el resorte de extensi\u00f3n Debe aclararse si el tipo de estr\u00e9s pretendido es un est\u00e1tico o un estr\u00e9s din\u00e1mico hechos. No se pueden dar valores generales de resistencia a la fatiga<\/p>\n","protected":false},"author":4,"featured_media":6937,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[476,895,898,899],"tags":[1482,1267,602,1484,1606,661],"class_list":["post-6935","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-conocimiento","category-muelles-de-alambre","category-muelles-de-traccion","category-muelles-de-traccion-sin-fin","tag-dynamische-beanspruchung-es","tag-osenformen-es","tag-schubspannung-es","tag-statische-beanspruchung-es","tag-tension-de-elevacion","tag-zugfedern-es"],"_links":{"self":[{"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/posts\/6935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/comments?post=6935"}],"version-history":[{"count":1,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/posts\/6935\/revisions"}],"predecessor-version":[{"id":6938,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/posts\/6935\/revisions\/6938"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/media\/6937"}],"wp:attachment":[{"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/media?parent=6935"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/categories?post=6935"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.federnshop.com\/es\/wp-json\/wp\/v2\/tags?post=6935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}